;| SK-NET TR4/16+ EISA Configuration File, Rev. 1.7 |
;| Copyright (C) Schneider & Koch & Co. Datensysteme GmbH 1991, 1993 |
;+ ----------------------------------------------------------------------+
BOARD
ID = "SKDD300"
NAME = "Schneider & Koch SK-NET TR4/16+ Token-Ring Adapter"
MFR = "Schneider & Koch"
CATEGORY = "NET"
SLOT = ISA16
LENGTH = 186
SKIRT = NO
READID = NO
BUSMASTER = 15
IOCHECK = INVALID
DISABLE = UNSUPPORTED
COMMENTS = "\nThe SK-NET TR4/16+ is a dual-speed (16 or 4 Mbps)
16-bit Token-Ring Adapter for ISA/EISA bus. It provides
UTP/STP cabling support with auto-detection facility.\n
As an intelligent busmaster board
it guarantees high performance data thruput, while offloading
the system processor from adapter management at the same time.\n
The installation will help you to get a conflict-free
configuration and suggests DIP switch settings as well as driver
configuration settings.
Be sure that your DIP-switch settings and software driver
configuration match exactly the selections made during
this installation procedure!"
SWITCH(1) = 8
NAME = "W1"
STYPE = DIP
VERTICAL = NO
REVERSE = YES
FACTORY = LOC(1-8) 10000000
COMMENTS = "This is the 8-position DIP-switch W1. Following items can be
configured through this switch:\n
W1.1 Busmaster Operating Mode\n
W1.2 - W1.5 RPL-ROM Base Address\n
W1.6 - W1.8 I/O Port Address\n
NOTE that W1.1 should always be ON (drives SA17..19!)"
SOFTWARE(1) = "
The software driver for the SK-NET TR4/16+ Token-Ring Adapter has to be
configured as follows:\n"
FUNCTION = "Token-Ring Network Adapter"
TYPE = "NET,TOK"
CONNECTION = "MIN-D9 or RJ-45: Token-Ring Lobe Cable."
SUBFUNCTION = "Connector Type"
TYPE = "CON"
COMMENTS = "The Min-D9 connector is for STP cable (eg. type 1 or
type 6) or for use with an external media filter.
The RJ-45 connector is for UTP cable (eg. type 3).\n
The SK-NET TR4/16+ will automatically detect the connector,
that is connencted to your ring!\n"
CHOICE = "MIN-D9/RJ-45 Auto-Detection"
SUBFUNCTION = "Busmaster Operating Mode"
COMMENTS = "The SK-NET TR4/16+ Token-Ring Adapter provides two busmaster
operating modes.\n
1) Adapter drives address lines SA<17..19>:\n
This mode is required, if the motherboard does not
drive SA<17..19> during busmaster operation.
Do not change that factory default configuration unless
you know exactly the way your motherboard treats
SA<17..19>.\n
2) Adapter does not drive address lines SA<17..19>:\n
This mode is required, to avoid any interference, if
the motherboard drives SA<17..19> during busmaster
operation.\n
NOTE that selecting the wrong mode can cause unpredictable
results to your system!"
CHOICE = "Adapter drives SA<17..19>"
LINK
INIT = SWITCH(1) LOC(1) 1
CHOICE = "Adapter does not drive SA<17..19>"
LINK
INIT = SWITCH(1) LOC(1) 0
SUBFUNCTION = "I/O Port Address"
COMMENTS = "If more than one SK-NET TR4/16+ adapter is located in your
computer, be sure to select a different I/O port address
for each adapter."
CHOICE = "0A20h"
LINK
PORT = 0A20h-0A3Fh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(6-8) 000
INIT = SOFTWARE(1) "I/O Port = 0A20h"
CHOICE = "1A20h"
LINK
PORT = 1A20h-1A3Fh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(6-8) 001
INIT = SOFTWARE(1) "I/O Port = 1A20h"
CHOICE = "0B20h"
LINK
PORT = 0B20h-0B3Fh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(6-8) 010
INIT = SOFTWARE(1) "I/O Port = 0B20h"
CHOICE = "1B20h"
LINK
PORT = 1B20h-1B3Fh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(6-8) 011
INIT = SOFTWARE(1) "I/O Port = 1B20h"
CHOICE = "0980h"
LINK
PORT = 0980h-099Fh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(6-8) 100
INIT = SOFTWARE(1) "I/O Port = 0980h"
CHOICE = "1980h"
LINK
PORT = 1980h-199Fh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(6-8) 101
INIT = SOFTWARE(1) "I/O Port = 1980h"
CHOICE = "0900h"
LINK
PORT = 0900h-091Fh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(6-8) 110
INIT = SOFTWARE(1) "I/O Port = 0900h"
CHOICE = "1900h"
LINK
PORT = 1900h-191Fh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(6-8) 111
INIT = SOFTWARE(1) "I/O Port = 1900h"
SUBFUNCTION = "RPL-ROM Base Address"
COMMENTS = "There are 8 possible 16K blocks of PC memory
for the RPL-ROM area.\n"
CHOICE = "RPL-ROM Disabled"
LINK
INIT = SWITCH(1) LOC(2-5) 0000
CHOICE = "C0000"
LINK
MEMORY = 16K
ADDRESS = 0C0000h
WRITABLE= NO
MEMTYPE = OTH
INIT = SWITCH(1) LOC(2-5) 1111
CHOICE = "C4000"
LINK
MEMORY = 16K
ADDRESS = 0C4000h
WRITABLE= NO
MEMTYPE = OTH
INIT = SWITCH(1) LOC(2-5) 1110
CHOICE = "C8000"
LINK
MEMORY = 16K
ADDRESS = 0C8000h
WRITABLE= NO
MEMTYPE = OTH
INIT = SWITCH(1) LOC(2-5) 1101
CHOICE = "CC000"
LINK
MEMORY = 16K
ADDRESS = 0CC000h
WRITABLE= NO
MEMTYPE = OTH
INIT = SWITCH(1) LOC(2-5) 1100
CHOICE = "D0000"
LINK
MEMORY = 16K
ADDRESS = 0D0000h
WRITABLE= NO
MEMTYPE = OTH
INIT = SWITCH(1) LOC(2-5) 1011
CHOICE = "D4000"
LINK
MEMORY = 16K
ADDRESS = 0D4000h
WRITABLE= NO
MEMTYPE = OTH
INIT = SWITCH(1) LOC(2-5) 1010
CHOICE = "D8000"
LINK
MEMORY = 16K
ADDRESS = 0D8000h
WRITABLE= NO
MEMTYPE = OTH
INIT = SWITCH(1) LOC(2-5) 1001
CHOICE = "DC000"
LINK
MEMORY = 16K
ADDRESS = 0DC000h
WRITABLE= NO
MEMTYPE = OTH
INIT = SWITCH(1) LOC(2-5) 1000
SUBFUNCTION = "Adapter Data Rate"
TYPE = "NET,TOK,SPD"
COMMENTS = "The SK-NET TR4/16+ Token-Ring Network adapter can operate
at two different data rates, 4 Mbps or 16 Mbps.
Be sure you select the proper adapter data rate according
to the data rate used on the Token-Ring Network LAN segment
your adapter is connected to.\n
This has to be done via software driver configuration."
CHOICE = "16 Mbps"
LINK
INIT = SOFTWARE(1) "Data Rate = 16 Mbps"
CHOICE = "4 Mbps"
LINK
INIT = SOFTWARE(1) "Data Rate = 4 Mbps"
SUBFUNCTION = "Interrupt"
TYPE = "NET,TOK,INT"
COMMENTS = "The SK-NET TR4/16+ Token-Ring Network adapter can operate
at seven different interrupt levels: 2 (9), 3, 5, 10,
11, 12 or 15.
Be sure to configure your software driver according to the
selection made here.\n
NOTE that adapter interrupts are edge-triggered and can not
be shared with any other device."
CHOICE = "IRQ 2(9)"
LINK
IRQ = 9
SHARE = NO
TRIGGER = EDGE
INIT = SOFTWARE(1) "IRQ = 2(9)"
CHOICE = "IRQ 3"
LINK
IRQ = 3
SHARE = NO
TRIGGER = EDGE
INIT = SOFTWARE(1) "IRQ = 3"
CHOICE = "IRQ 5"
LINK
IRQ = 5
SHARE = NO
TRIGGER = EDGE
INIT = SOFTWARE(1) "IRQ = 5"
CHOICE = "IRQ 10"
LINK
IRQ = 10
SHARE = NO
TRIGGER = EDGE
INIT = SOFTWARE(1) "IRQ = 10"
CHOICE = "IRQ 11"
LINK
IRQ = 11
SHARE = NO
TRIGGER = EDGE
INIT = SOFTWARE(1) "IRQ = 11"
CHOICE = "IRQ 12"
LINK
IRQ = 12
SHARE = NO
TRIGGER = EDGE
INIT = SOFTWARE(1) "IRQ = 12"
CHOICE = "IRQ 15"
LINK
IRQ = 15
SHARE = NO
TRIGGER = EDGE
INIT = SOFTWARE(1) "IRQ = 15"
SUBFUNCTION = "Data Transfer Mode"
TYPE = "NET,TOK,MOD"
COMMENTS = "The SK-NET TR4/16+ Token-Ring Network adapter can operate
with or without busmaster mode. When operating as a
busmaster, three DMA channels can be used: 5, 6 or 7.
Otherwise Programmed I/O (PIO) operation mode is used,
slowing down the performance, but making it possible,
to use the SK-NET Token-Ring card even in a PC, that
does not support ISA busmastering.\n
Be sure to configure your drivers according to the selection
made here."
CHOICE = "Busmaster DMA 5"
SUBTYPE = "Master5"
LINK
DMA = 5
SHARE = NO
TIMING = DEFAULT
INIT = SOFTWARE(1) "DMA = 5"
CHOICE = "Busmaster DMA 6"
SUBTYPE = "Master6"
LINK
DMA = 6
SHARE = NO
TIMING = DEFAULT
INIT = SOFTWARE(1) "DMA = 6"
CHOICE = "Busmaster DMA 7"
SUBTYPE = "Master7"
LINK
DMA = 7
SHARE = NO
TIMING = DEFAULT
INIT = SOFTWARE(1) "DMA = 7"